Thank You both for your input but your suggesstion is what I did initially
and it didn't work hence my research.
TWO NIC server, 444 open ( inaddition to 443 and 4125 ) I am seeing
reference to port 80 needing to be open, surely this cant be right?
Works fine internally Cant understand why it wont work from ' remote ' page
and doesn't even work from fqdn:444
Thanks Again
"Merv Porter" <mwport@newsgroup_spam_hotmail.com> wrote in message
news:er1oPxlWKHA.1280@newsgroup
>I think your right Susan. I believe that KB relates to SBS 2003 RTM and
>the problem it fixes was addressed in SBS 2003 SP1. So re-run CEICW,
>select to enable the firewall, and on the Web Services Configuration
>screen, select to allow Windows Sharepoint Services Intranet Site.
>
> --
> Merv Porter [SBS-MVP]
> ============================
>
> "Susan Bradley" <sbradcpa@newsgroup> wrote in message
> news:OP9dMClWKHA.408@newsgroup
>> Teneo wrote:
>>> I need to configure companyweb for remote users, preferable not open
>>> direct to internet but accessible via ' https://fqdn/remote '
>>>
>>> Server in question is SBS 2003 premium and found these instructions...
>>>
>>> http://support.microsoft.com/kb/838304
>>>
>>> Surely this cant be right in todays technological advancement! Document
>>> is Dec 2007. Change registry entries ! AND more importantly if I run
>>> CEICW the registry entries get changed so I have to remember this
>>> configuration and change registry entries again.... :-)
>>>
>>> This refers to ISA 2000. This server has SP1 with ISA 2004. Am I to
>>> assume same steps for ISA 2004 or does anyone know of other instructions
>>> ?
>>>
>>>
>>>
>>> >> I think you just run the CEICW with 2004 as I recall. >